range of product |
Preventa Safety automation
|
|
---|---|---|
product or component type |
Preventa safety module
|
|
safety module name |
XPSAK
|
|
safety module application |
For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
|
|
function of module |
Proximity sensor monitoring
Emergency stop monitoring 1-channel wiring Monitoring of electro-sensitive protection equipment (ESPE) Multiple emergency stop monitoring 2-channel wiring Monitoring of a movable guard Sensing mat and edges monitoring Emergency stop with 2 NC contacts monitoring 2-channel wiring Monitoring of a movable guard associated with 2 switches and automatic start |
|
safety level |
Can reach PL e/category 4 conforming to EN/ISO 13849-1
Can reach SILCL 3 conforming to EN/IEC 62061 |
|
safety reliability data |
DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 154.5 years conforming to EN/ISO 13849-1 PFHd = 7.39E-9 1/h conforming to EN/IEC 62061 |
|
type of start |
Configurable
|
|
connections – terminals |
Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25…1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25…1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25…2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5…2 x 1.5 mm² flexible with cable end, with double bezel |
|
output type |
Relay instantaneous opening, 3 NO circuit(s), volt-free
|
|
number of additional circuits |
1 NC + 4 solid state outputs
|
|
[Us] rated supply voltage |
24 V AC – 15…10 %
24 V DC – 15…10 % |
synchronisation time between inputs |
Unlimited (manual start)
2 or 4 s depending of wiring (automatic start) |
|
---|---|---|
supply frequency |
50/60 Hz
|
|
maximum power consumption in VA |
5 VA AC
|
|
input protection type |
Internal, electronic
|
|
[Uc] control circuit voltage |
24 V DC
|
|
maximum line resistance |
28 Ohm
|
|
breaking capacity |
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output |
|
breaking capacity |
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
|
|
output thermal current |
6 A per relay for relay output
|
|
[Ith] conventional free air thermal current |
18 A
|
|
associated fuse rating |
4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
|
minimum output current |
10 mA for relay output
|
|
minimum output voltage |
17 V for relay output
|
|
maximum response time on input open |
40 ms
|
|
[Ui] rated insulation voltage |
300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 |
|
[Uimp] rated impulse withstand voltage |
4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1 |
|
local signalling |
4 LEDs
|
|
current consumption |
30 mA at 24 V AC on power supply
|
|
mounting support |
35 mm symmetrical DIN rail
|
|
net weight |
0.3 kg
|