0 items$0.00

No products in the cart.

Module XPSAK – Emergency stop – 24 V AC DC

Maker: Schneider Electric

Model: XPSAK

range of product
Preventa Safety automation
product or component type
Preventa safety module
safety module name
XPSAK
safety module application
For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
function of module
Proximity sensor monitoring
Emergency stop monitoring 1-channel wiring
Monitoring of electro-sensitive protection equipment (ESPE)
Multiple emergency stop monitoring 2-channel wiring
Monitoring of a movable guard
Sensing mat and edges monitoring
Emergency stop with 2 NC contacts monitoring 2-channel wiring
Monitoring of a movable guard associated with 2 switches and automatic start
safety level
Can reach PL e/category 4 conforming to EN/ISO 13849-1
Can reach SILCL 3 conforming to EN/IEC 62061
safety reliability data
DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 154.5 years conforming to EN/ISO 13849-1
PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
type of start
Configurable
connections – terminals
Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14…1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25…1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25…1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14…2 x 0.75 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25…2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5…2 x 1.5 mm² flexible with cable end, with double bezel
output type
Relay instantaneous opening, 3 NO circuit(s), volt-free
number of additional circuits
1 NC + 4 solid state outputs
[Us] rated supply voltage
24 V AC – 15…10 %
24 V DC – 15…10 %
Complementary
synchronisation time between inputs
Unlimited (manual start)
2 or 4 s depending of wiring (automatic start)
supply frequency
50/60 Hz
maximum power consumption in VA
5 VA AC
input protection type
Internal, electronic
[Uc] control circuit voltage
24 V DC
maximum line resistance
28 Ohm
breaking capacity
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
breaking capacity
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
output thermal current
6 A per relay for relay output
[Ith] conventional free air thermal current
18 A
associated fuse rating
4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
minimum output current
10 mA for relay output
minimum output voltage
17 V for relay output
maximum response time on input open
40 ms
[Ui] rated insulation voltage
300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage
4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1
local signalling
4 LEDs
current consumption
30 mA at 24 V AC on power supply
mounting support
35 mm symmetrical DIN rail
net weight
0.3 kg
Category: